Ambient seismic noise measurements were conducted inside the Holweide Hospital (Cologne) for checking whether its frequencies of vibration fall into the range where soil amplification is expected. If this is the case, damage might increase in case of an earthquake due to an amplified structural response of the building. Two different techniques were used: the ratio between the horizontal and vertical components of the spectra recorded at stations located inside the building and the ratio between the corresponding components of the spectra recorded simultaneously inside the building and at a reference station placed outside. While the former method might be preferred because of less equipment involved, the latter has the advantage of producing more stable results and deleting automatically the influence of the sedimentary cover, which might obscure some eigenfrequencies of vibration of the building. An independently performed finite-element analysis of the hospital showed a good correlation between measured and calculated eigenmodes.

Assessing the vibrational frequencies of the Holweide Hospital in the city of Cologne (Germany) by means of ambient seismic noise analysis and FE modelling

Parolai S.;
2005-01-01

Abstract

Ambient seismic noise measurements were conducted inside the Holweide Hospital (Cologne) for checking whether its frequencies of vibration fall into the range where soil amplification is expected. If this is the case, damage might increase in case of an earthquake due to an amplified structural response of the building. Two different techniques were used: the ratio between the horizontal and vertical components of the spectra recorded at stations located inside the building and the ratio between the corresponding components of the spectra recorded simultaneously inside the building and at a reference station placed outside. While the former method might be preferred because of less equipment involved, the latter has the advantage of producing more stable results and deleting automatically the influence of the sedimentary cover, which might obscure some eigenfrequencies of vibration of the building. An independently performed finite-element analysis of the hospital showed a good correlation between measured and calculated eigenmodes.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14083/2592
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 29
social impact