This paper deals with the neo-deterministic definition of the seismic input in the municipality of Nimis (Italy), aimed at the design of residential seismically isolated buildings. The seismic input is defined by the computation of realistic synthetic seismograms considering different levels of detail for the earthquake source, both for a bedrock model and taking into account the specific site conditions. The horizontal response spectrum, calculated in the centre of the municipality by modelling the most dangerous source, advises against the construction of a building with a fixed base, but it is compatible with the seismic isolation, and it has been, therefore, used for the design of a residential seismically isolated building. The maximum displacement for the isolation system has been estimated about 17 cm, a value much lower than that provided by the code design response spectrum (28 cm). The importance of the realistic modelling, which permits the generalization of empirical observations by means of, physically sound, theoretical considera- tions, is evident, as it allows for the optimisation of the structural design with respect to the site of interest

Neo-deterministic definition of seismic input for residential seismically isolated buildings

Zuccolo E.;Peresan A.;
2008-01-01

Abstract

This paper deals with the neo-deterministic definition of the seismic input in the municipality of Nimis (Italy), aimed at the design of residential seismically isolated buildings. The seismic input is defined by the computation of realistic synthetic seismograms considering different levels of detail for the earthquake source, both for a bedrock model and taking into account the specific site conditions. The horizontal response spectrum, calculated in the centre of the municipality by modelling the most dangerous source, advises against the construction of a building with a fixed base, but it is compatible with the seismic isolation, and it has been, therefore, used for the design of a residential seismically isolated building. The maximum displacement for the isolation system has been estimated about 17 cm, a value much lower than that provided by the code design response spectrum (28 cm). The importance of the realistic modelling, which permits the generalization of empirical observations by means of, physically sound, theoretical considera- tions, is evident, as it allows for the optimisation of the structural design with respect to the site of interest
2008
Synthetic seismograms Site effects Seismic isolation
File in questo prodotto:
File Dimensione Formato  
Neo-deterministic definition of seismic input for residential seismically isolated buildings.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 1.93 MB
Formato Adobe PDF
1.93 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14083/27260
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 24
social impact